Email

Model ADW-SP16

Weighing Controller with up to 16 Setpoints

Model_ADW_SP16_4e60aef610931.jpg
Download product tech sheet
To view in your browser: Left-Click on the icon. To save: Right-Click on icon / Save Target As

The DIN rail mounted remote relay units offer an increased number of set points over that provided by a standard ADW15 strain gauge indicator/controller.

This allows for multi action operations such as batch and recipe control. The software of the ADW-SP16 gives the user freedom to program the number of set points for their requirements. A single ADW-SP16 will control up to 16 set points, programmed from its front panel.

Set points can be individually set up with In Flight compensation and hysteresis values. Separate 'Output Latch' and 'Output Action' for up to 14 of the 16 set points is available, settable from the front panel of the ADW-SP16. A special mnemonic allows the user to specify the number of set points to be used.

All relays are pluggable and connections are made via field screw terminals.

  • Up to 16 setpoints, each with an associated SPCO relay (on DIN rail module)
  • Individual set point, In-flight & hysterisis values
  • Programmable from the ADW keypad
  • Relay contact rating 230V @ 5A AC
  • Communications and Printer Driver
  • Simple one pass auto calibration for minimum set-up time on site
  • Provides excitation of 10V @ 160mA to drive up to 6 x 350 Ohm load cells
  • Variable gain input sensitivity from 0.5 to 200 mV/V
  • 6 wire input to compensate for zener barrier and cable losses
  • RS232 or RS485 communications for setup, data transfer or label/ticket printing
Calibration
Automatic or Manual
 
Sensitivity
Preset via DIL switches between 0.5 to 200mV/V
 
Excitation
10V DC nominal, 150mA maximum
 
Accuracy
90 days ± 0.08% of reading ± 0.05% of FSD typical
 
Drift
0.002%ºC typical @ 2.5mV/V
 
Display Rate
0.1 seconds for standard update
 
DC Voltage
0 to 5V, 0 to 10V, -10 to +10V, Max Current out 50mA
 
Accuracy
typical ± 0.08% of output, ± 0.08%FSD